16946 Bug Fixed with Hotfix Medium Failure Tree and EFC Tree - While clicking Expand/Collapse arrows in Failure Tree and EFC Tree, diagrams are partially displayed. (Refer Description) 06/15/2020 04:26 PM Shankar Narayanan RFD Cycle 6 SP 10.0.0 06/05/2020 06/05/2020 07:13 PM 06/15/2020 11:58 AM

1.Login as RFD module administrator

2.Click on Main and select any PI

3.Select Failure Analysis Click on the Expand arrow, and collapse it

4.Observe the diagram

Actions
16944 Bug Fixed with Hotfix Medium Combined Interface Matrix - Displays No values of In DFMEA and Interface link Cells also. 06/15/2020 04:26 PM Shankar Narayanan RFD Cycle 6 SP 10.0.0 06/05/2020 06/05/2020 04:25 PM 06/15/2020 12:07 PM

1.Login as RFD module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Interface Function Matrix option

4.Double click on any cell and select Risk as H

5.Again double click on any cell and select X or N

6.Now Double click on the interface line cell and select M

7.Open Combined Interface Matrix and observe the allocations

Actions
16931 Bug Fixed with Hotfix Medium Architectural/ Block Diagram - Following issues occurs in Block Diagam (Refer Description) 06/15/2020 04:27 PM Shankar Narayanan RFD Cycle 6 SP 10.0.0 06/04/2020 06/04/2020 02:06 PM 06/15/2020 12:13 PM

1.Login as RFD module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Architectural/Block Diagram

4.Click on Select context element and select it

5.Click on OK button and observe the New tab

6.Observe the PI name on top of the Scope

7.Drag an external element and drop it inside the scope

8.Observe the alert

Actions
16929 Bug Fixed with Hotfix Medium In Add Records pop up screen Site is displayed as 1 06/10/2020 10:42 AM Ragavi Ram DOCPRO Cycle 6 Jacqueline Antonette SP 10.0.0 06/03/2020 06/03/2020 07:27 PM

1.Login into EwQIMS Application
2.Click on Documents
3.Right click the Document number
4.Select Add Record
5.In Add Record Pop up the site is displayed as 1. It should display corporate

Actions
16924 Bug Fixed with Hotfix Medium After adding users to group the Top menu is getting hidden 06/10/2020 10:42 AM Ragavi Ram DOCPRO Cycle 6 Raghu Ram SP 10.0.0 06/03/2020 06/03/2020 04:12 PM

1.Login into EwQIMS Application
2.Go to Doc Pro
3.Click on Groups
4.Add user by clicking on user Icon
5.Click on save and observer the function

Actions
16914 Bug Fixed with Hotfix Medium While publishing the "requirement allocation document" It is showing as already published. 06/08/2020 06:55 PM malini C APQPPPAP MGR Cycle 6 SP 10.0.0 06/02/2020 06/02/2020 04:12 PM

1'Login to EWQIMS
2. Select APQP
3. Attach FST input Document for "requirement allocation document"(vis deliverable info or overall PI linkage)
4. Try to publish and see the behaviour

Actions
16895 Bug Fixed with Hotfix Medium Interface Function Matrix - Add/Remove element is not opening in IFM. (Refer Description) 06/15/2020 04:25 PM Shankar Narayanan FST Cycle 5 SP 10.0.0 05/30/2020 05/30/2020 03:48 PM 06/15/2020 12:17 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Interface Function Matrix option

4.Click on Add/Remove Elements button and observe the result

Actions
16894 Bug Fixed with Hotfix Medium Process VDA - Functional/Failure Analysis - While creating FourM from Tree/Table view, it is duplicating the FourM 06/15/2020 04:22 PM Shankar Narayanan VDA Cycle 5 SP 10.0.0 05/29/2020 05/29/2020 09:32 PM 06/15/2020 02:31 PM

1.Login as AQuA Pro Module Administrator

2.Click on AQuA Pro Tab and click on Main Menu

3.Right click on the Global PI and Select a Production Item

4.Click on the AIAG-VDA Design Menu. New window will open

5.Click on Process VDA tab and select Functional/Failure Analysis

6.Right click on Characteristics and select Create FourM option

7.Create a FourM and click on Done button

8.Observe the Screen

Actions
16889 Bug Fixed with Hotfix Medium Process VDA- Structure Analysis - While adding a newly created FourM for more than one time, system duplicates that FourM alone. (Refer Steps to Reproduce) 06/15/2020 04:23 PM Shankar Narayanan VDA Cycle 5 SP 10.0.0 05/29/2020 05/29/2020 03:29 PM 06/15/2020 02:28 PM

1.Login as AQuA Pro Module Administrator

2.Click on AQuA Pro Tab and click on Main Menu

3.Right click on the Global PI and Select a Production Item

4.Click on the AIAG-VDA Design Menu. New window will open

5.Click on Process VDA tab and select Structure Analysis

6.Create an Operation and One FourM

7.Now create another FourM for same Operattion

8.Add that newly created FourM and click Done

9.Again add the same FourM and click Done

10.Observe the Duplication

Actions
16888 Bug Fixed with Hotfix Medium The Published FST document is showing with a different name in docpro actions page. 06/08/2020 06:55 PM malini C APQPPPAP MGR Cycle 5 SP 10.0.0 05/29/2020 05/29/2020 02:10 PM

1. Login to EWQIMS
2. Select an APQP project and Link FST documents
3. Publish the document (with Approval)
4. Login as approver
5. Check for the document name showing for the published document

Actions
16849 Bug Fixed with Hotfix Medium (THEMES) Except Ewqims theme system does not display the icon for FourM for all other themes. 06/15/2020 04:24 PM Shankar Narayanan VDA Cycle 4 SP 10.0.0 05/21/2020 05/21/2020 07:57 PM 06/15/2020 02:57 PM

1.Login as AQuA Pro Module Administrator

2.Click on AQuA Pro Tab and click on Main Menu

3.Right click on the Global PI and Select a Production Item

4.Click on the AIAG-VDA Design Menu. New window will open

5.Click on Process VDA tab and select Functional Analysis

6.Observe the Icon for FourM

Actions
16801 Bug Fixed with Hotfix Medium Reports: PI Names listing as double (Refer the Screenshot) 06/03/2020 04:37 PM Anonymous AQUAPRO Cycle 4 SP 10.0.0 05/19/2020 05/19/2020 05:11 PM 06/03/2020 02:14 PM

1.Login as AQuAPro Module User

2.Click on AQuAPro Tab -> Main/Main2

3.Expand Global PI -> Select any of the PI

4.Publish Process Flow & Control Plan (Don't Publish PFMEA Document)

5.Click on Reports Tab -> Open any Report (Process Reports)

6.Click the PI dropdown list

7.Observe the Result

Actions
16742 Bug In Progress Medium Dynamic Preliminary Architecture - Inner child elements must not be allowed to drop separately(Refer Description) 05/18/2020 08:55 PM Shankar Narayanan FST Cycle 3 SP 10.0.0 05/13/2020 05/13/2020 01:30 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Dynamic Preliminary Architecture

4.Drag a child element and drop on the scope.

Actions
16691 Bug Not Resolved Medium State Transition Diagram - Following issues occurs in State Transition Diagram 05/20/2020 02:45 PM Shankar Narayanan FST Cycle 3 SP 10.0.0 05/08/2020 05/08/2020 05:38 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on State Transition Diagram

4.Add a text and resize it

5.Click on the clone option

Actions
16607 Reports Resolved Medium When the threshold limit is selected more than 3 months then not displaying in the reports 05/27/2020 07:06 PM Anonymous APQPPPAP MGR Cycle 2 Sakthivel P SP 10.0.0 05/04/2020 05/04/2020 05:15 PM

1. Login to wqims
2. Select APQP Module
3. Click on Reports and Select Resource Allocation Report

Actions
16603 Reports Resolved Medium The Resource Search Option in the Resource Allocation report is not working. 05/08/2020 07:43 PM malini C APQPPPAP MGR Cycle 2 Sakthivel P SP 10.0.0 05/04/2020 05/04/2020 03:43 PM

1. Login to wqims
2. Select APQP Module
3. Click on Reports and Select Resource Allocation Report
4. Enter a name on Resource Search field and see the result

Actions
16579 Bug Fixed with Hotfix Medium Add/Remove Elements popup - In all the Add/Remove Element popup, the last BOM element displays Undefined PI 06/05/2020 07:19 PM Shankar Narayanan FST Cycle 2 SP 10.0.0 04/30/2020 04/30/2020 06:59 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Block Diagram

4.Click on Add/Remove Element button and expand all the element

Actions
16429 Bug Fixed with Hotfix Medium Cummins Reports-If commodity contains & ampersend symbol (Eg;Labels & Stickers) the special character(&) shows as &.Pls refer sceen shot 06/12/2020 11:23 AM Saradha Balan SUPPLIER MANAGEMENT Cycle 1 SP 10.0.0 04/21/2020 04/21/2020 02:21 PM 05/28/2020 04:14 PM

Cummins Reports-If commodity contains & ampersend symbol (Eg;Labels & Stickers) the special character(&) shows as &.Pls refer sceen shot

Actions
    (1-18/18)