16946 Bug Fixed with Hotfix Medium Failure Tree and EFC Tree - While clicking Expand/Collapse arrows in Failure Tree and EFC Tree, diagrams are partially displayed. (Refer Description) 06/15/2020 04:26 PM Shankar Narayanan RFD Cycle 6 SP 10.0.0 06/05/2020 06/05/2020 07:13 PM 06/15/2020 11:58 AM

1.Login as RFD module administrator

2.Click on Main and select any PI

3.Select Failure Analysis Click on the Expand arrow, and collapse it

4.Observe the diagram

Actions
16944 Bug Fixed with Hotfix Medium Combined Interface Matrix - Displays No values of In DFMEA and Interface link Cells also. 06/15/2020 04:26 PM Shankar Narayanan RFD Cycle 6 SP 10.0.0 06/05/2020 06/05/2020 04:25 PM 06/15/2020 12:07 PM

1.Login as RFD module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Interface Function Matrix option

4.Double click on any cell and select Risk as H

5.Again double click on any cell and select X or N

6.Now Double click on the interface line cell and select M

7.Open Combined Interface Matrix and observe the allocations

Actions
16931 Bug Fixed with Hotfix Medium Architectural/ Block Diagram - Following issues occurs in Block Diagam (Refer Description) 06/15/2020 04:27 PM Shankar Narayanan RFD Cycle 6 SP 10.0.0 06/04/2020 06/04/2020 02:06 PM 06/15/2020 12:13 PM

1.Login as RFD module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Architectural/Block Diagram

4.Click on Select context element and select it

5.Click on OK button and observe the New tab

6.Observe the PI name on top of the Scope

7.Drag an external element and drop it inside the scope

8.Observe the alert

Actions
16928 Bug Fixed with Hotfix High Design VDA - Added Risk data are not displayed anywhere. 06/15/2020 04:21 PM Shankar Narayanan VDA Cycle 6 SP 10.0.0 06/03/2020 06/03/2020 05:50 PM 06/15/2020 02:49 PM

1.Login as AQuA Pro Module Administrator

2.Click on AQuA Pro Tab and click on Main Menu

3.Right click on the Global PI and Select a Production Item

4.Click on the AIAG-VDA Design Menu. New window will open

5.Click on Design VDA tab and select Failure Analysis menu

6.Add Risk values in Risk popup and click OK

7.Observe the Screen or DFMEA

Actions
16898 Bug Fixed with Hotfix High Process VDA - Functional/Failure Analysis - Items created from Tree/Table view is created twice in the table and Diagrammatic view. 06/15/2020 04:22 PM Shankar Narayanan VDA Cycle 5 SP 10.0.0 06/01/2020 06/01/2020 11:54 AM 06/15/2020 02:34 PM

1.Login as AQuA Pro Module Administrator

2.Click on AQuA Pro Tab and click on Main Menu

3.Right click on the Global PI and Select a Production Item

4.Click on the AIAG-VDA Design Menu. New window will open

5.Click on Process VDA tab and select Functional/Failure Analysis

6.Right click on the Oper in Tree view and Create Characteristics

7.Create Fourm,Process Item Function, Work Element Function, Cause, Effect etc and observe the Diagram view

Actions
16895 Bug Fixed with Hotfix Medium Interface Function Matrix - Add/Remove element is not opening in IFM. (Refer Description) 06/15/2020 04:25 PM Shankar Narayanan FST Cycle 5 SP 10.0.0 05/30/2020 05/30/2020 03:48 PM 06/15/2020 12:17 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Interface Function Matrix option

4.Click on Add/Remove Elements button and observe the result

Actions
16894 Bug Fixed with Hotfix Medium Process VDA - Functional/Failure Analysis - While creating FourM from Tree/Table view, it is duplicating the FourM 06/15/2020 04:22 PM Shankar Narayanan VDA Cycle 5 SP 10.0.0 05/29/2020 05/29/2020 09:32 PM 06/15/2020 02:31 PM

1.Login as AQuA Pro Module Administrator

2.Click on AQuA Pro Tab and click on Main Menu

3.Right click on the Global PI and Select a Production Item

4.Click on the AIAG-VDA Design Menu. New window will open

5.Click on Process VDA tab and select Functional/Failure Analysis

6.Right click on Characteristics and select Create FourM option

7.Create a FourM and click on Done button

8.Observe the Screen

Actions
16889 Bug Fixed with Hotfix Medium Process VDA- Structure Analysis - While adding a newly created FourM for more than one time, system duplicates that FourM alone. (Refer Steps to Reproduce) 06/15/2020 04:23 PM Shankar Narayanan VDA Cycle 5 SP 10.0.0 05/29/2020 05/29/2020 03:29 PM 06/15/2020 02:28 PM

1.Login as AQuA Pro Module Administrator

2.Click on AQuA Pro Tab and click on Main Menu

3.Right click on the Global PI and Select a Production Item

4.Click on the AIAG-VDA Design Menu. New window will open

5.Click on Process VDA tab and select Structure Analysis

6.Create an Operation and One FourM

7.Now create another FourM for same Operattion

8.Add that newly created FourM and click Done

9.Again add the same FourM and click Done

10.Observe the Duplication

Actions
16849 Bug Fixed with Hotfix Medium (THEMES) Except Ewqims theme system does not display the icon for FourM for all other themes. 06/15/2020 04:24 PM Shankar Narayanan VDA Cycle 4 SP 10.0.0 05/21/2020 05/21/2020 07:57 PM 06/15/2020 02:57 PM

1.Login as AQuA Pro Module Administrator

2.Click on AQuA Pro Tab and click on Main Menu

3.Right click on the Global PI and Select a Production Item

4.Click on the AIAG-VDA Design Menu. New window will open

5.Click on Process VDA tab and select Functional Analysis

6.Observe the Icon for FourM

Actions
16808 Bug Fixed with Hotfix Low Block Diagram - Alignment for menus are not good. ( Fire Fox) 06/15/2020 04:25 PM Shankar Narayanan FST Cycle 4 SP 10.0.0 05/20/2020 05/20/2020 01:18 PM 06/15/2020 03:15 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Architectural /Block Diagram

4.Observe the Icon for Published document and Enable Automate Block Diagram checkbox

Actions
16742 Bug In Progress Medium Dynamic Preliminary Architecture - Inner child elements must not be allowed to drop separately(Refer Description) 05/18/2020 08:55 PM Shankar Narayanan FST Cycle 3 SP 10.0.0 05/13/2020 05/13/2020 01:30 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Dynamic Preliminary Architecture

4.Drag a child element and drop on the scope.

Actions
16691 Bug Not Resolved Medium State Transition Diagram - Following issues occurs in State Transition Diagram 05/20/2020 02:45 PM Shankar Narayanan FST Cycle 3 SP 10.0.0 05/08/2020 05/08/2020 05:38 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on State Transition Diagram

4.Add a text and resize it

5.Click on the clone option

Actions
16676 Bug Fixed with Hotfix Low Process VDA- Create and Map option - Close icon is not aligned properly in RHS 06/15/2020 04:24 PM Shankar Narayanan VDA Cycle 3 SP 10.0.0 05/08/2020 05/08/2020 02:23 PM 06/15/2020 01:34 PM

1.Login as AQuA Pro Module Administrator

2.Click on AQuA Pro Tab and click on Main Menu

3.Right click on the Global PI and Select a Production Item

4.Click on the AIAG-VDA Design Menu. New window will open

5.Click on Process VDA tab and select Functional/Failure Analysis

6.Right click on Operation in LHS and select Create and Map option

7.Select any one option and observe the RHS

Actions
16671 Bug Fixed with Hotfix Low HARA - While adding Malfunction and Safety goal, the last line is not displayed. 06/15/2020 04:25 PM Shankar Narayanan FST Cycle 3 SP 10.0.0 05/08/2020 05/08/2020 01:54 PM 06/15/2020 12:28 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select HARA and add Operation Situation/Malfunction/Safety goal

4.Observe the line from Malfunction and Safety goal

Actions
16670 Bug In Progress High Architectural/Block Diagram - All the least level elements which does not have any child element alone is displayed in the Vertical scope box. 05/28/2020 02:22 PM Shankar Narayanan FST Cycle 4 SP 10.0.0 05/08/2020 05/08/2020 01:02 PM 05/20/2020 02:19 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Architectural/Block Diagram

4.Click on Add/Remove Element button and select all the elements and click OK

5.Observe the diagram

Actions
16646 Bug Resolved High DFMEA and PFMEA(Risk Analysis) - After entering data for Current Prevention Control (PC) of FC and Current Detection Control (DC) of FC or FM system displays error 06/11/2020 11:13 AM Shankar Narayanan AQUAPRO Cycle 2 SP 10.0.0 05/05/2020 05/05/2020 03:18 PM

1.Login as AQuA Pro Module Administrator

2.Click on AQuA Pro Tab and click on Main Menu

3.Right click on the Global PI and Select a Production Item

4.Click on the AIAG-VDA Design Menu. New window will open

5.Click on Design/Process VDA tab and select DFMEA/PFMEA

6.Enter the data for Risk Analysis

Actions
16579 Bug Fixed with Hotfix Medium Add/Remove Elements popup - In all the Add/Remove Element popup, the last BOM element displays Undefined PI 06/05/2020 07:19 PM Shankar Narayanan FST Cycle 2 SP 10.0.0 04/30/2020 04/30/2020 06:59 PM

1.Login as FST module administrator

2.Click on Main and select any PI

3.Select Item Definition menu and click on Block Diagram

4.Click on Add/Remove Element button and expand all the element

Actions
    (1-17/17)