Project

General

Profile

Actions

Bug #30207

open

FSR - ASIL value Display Issue After Adding One More Function to Safety Goal (NON STD ASIL CONCEPTS - SME clarifucation needed)

Added by Vani Kunnatheri 2 months ago. Updated 3 days ago.

Status:
Not Resolved
Priority:
Medium
Start date:
02/14/2025
Due date:
% Done:

0%

Estimated time:
Steps To Reproduce:

1.Log into FSR
2.Locate A standard SG D, non stnadard C and B
3.Add a function and requiremnt against C
4.Use same on B
5.Add one more function under C
6.Please observe B
7.Add same function against D
8.Please observe

MODULES:
FST
Build Cycle:
Cycle 1
Customer:
Issue Dependency:
Dev Commitment to Resolve in::

Description

When I reused the same functions under non-standard safety goals C and * B* , the system displayed the highest ASIL value as expected. However, * after adding a new function (as a function branch) under safety goal C* , the highest ASIL value is no longer being displayed for safety goal B . Furthermore, when I added the same function under safety goal D, it displayed the ASIL for C instead of the expected ASIL for D.



Files

clipboard-202502141050-ngm7r.png (48.7 KB) clipboard-202502141050-ngm7r.png Vani Kunnatheri, 02/14/2025 09:20 PM
clipboard-202502141051-initn.png (47.4 KB) clipboard-202502141051-initn.png Vani Kunnatheri, 02/14/2025 09:21 PM
clipboard-202503070857-wj6nq.png (37.7 KB) clipboard-202503070857-wj6nq.png Vani Kunnatheri, 03/07/2025 07:27 PM
Actions #1

Updated by Manivannan Uppiliappan 2 months ago

  • Status changed from New to Open
  • Assignee changed from chitra Kalangiam to Manivannan Uppiliappan
Actions #2

Updated by Manivannan Uppiliappan 2 months ago

  • Status changed from Open to Fixed in Dev
Actions #3

Updated by Manivannan Uppiliappan 2 months ago

  • Status changed from Fixed in Dev to Resolved
Actions #4

Updated by Vani Kunnatheri about 1 month ago

Issue with non standard asil alone fixed , but when we add same function against standard D , highest asil not applies to non standrad asils

Actions #5

Updated by Manivannan Uppiliappan about 1 month ago

  • Subject changed from FSR - ASIL value Display Issue After Adding One More Function to Safety Goal to FSR - ASIL value Display Issue After Adding One More Function to Safety Goal (NON STD ASIL CONCEPTS)
Actions #6

Updated by Manivannan Uppiliappan about 1 month ago

  • Subject changed from FSR - ASIL value Display Issue After Adding One More Function to Safety Goal (NON STD ASIL CONCEPTS) to FSR - ASIL value Display Issue After Adding One More Function to Safety Goal (NON STD ASIL CONCEPTS - SME clarifucation needed)
Actions #7

Updated by Vani Kunnatheri 3 days ago

  • Project changed from SP 11.2.0.18 Patches to SP 11.3.2.2 Patches
Actions #8

Updated by Vani Kunnatheri 3 days ago

moved from sp 112018 to 11322

Actions

Also available in: Atom PDF