Actions
Feature/Enhancement #30163
openFSR - Non-Standard Safety Goal Fails to Meet Higher ASIL Requirements When Same Function is Applied [NON STANDARD ASIL concept SME clarification needed]
Start date:
02/06/2025
Due date:
% Done:
0%
Estimated time:
Steps To Reproduce:
1.Log into FSR
2.Locate 2 standard safety goals and 1 non standard safety goal
3.Add same function across all
4.Observe the non standard safety goal
MODULES:
FST
Build Cycle:
Cycle 4
Customer:
Issue Dependency:
Moved from SP11.3.2 to SP 11.3.2.2
Dev Commitment to Resolve in::
Description
1.The system has two standard safety goals and one non-standard safety goal. However, the non-standard safety goal does not meet the higher ASIL requirements.
When the same function is applied across all three safety goals, the non-standard safety goal fails to satisfy the higher ASIL concept.
step 1:
step 2:
2.It directly fails when same function applied across two different safety goals too
Files
Updated by Vani Kunnatheri 2 months ago
- File clipboard-202502061129-udd5f.png clipboard-202502061129-udd5f.png added
- Subject changed from FSR - Non-Standard Safety Goal Fails to Meet Higher ASIL Requirements When Same Function is Applied (with minimum 3 safety goals) to FSR - Non-Standard Safety Goal Fails to Meet Higher ASIL Requirements When Same Function is Applied
- Description updated (diff)
Updated by Manivannan Uppiliappan 2 months ago
- Status changed from New to Open
- Assignee changed from chitra Kalangiam to Manivannan Uppiliappan
Updated by Manivannan Uppiliappan 2 months ago
- Status changed from Open to Resolved
Updated by Vani Kunnatheri about 1 month ago
- File clipboard-202503140852-dztnb.png clipboard-202503140852-dztnb.png added
- Status changed from Resolved to Not Resolved
- How do we missed in Testing ? set to Impact of another change
issue not fixed on 11321
Updated by Manivannan Uppiliappan about 1 month ago
- Subject changed from FSR - Non-Standard Safety Goal Fails to Meet Higher ASIL Requirements When Same Function is Applied to FSR - Non-Standard Safety Goal Fails to Meet Higher ASIL Requirements When Same Function is Applied [NON STANDARD ASIL concept SME clarification needed]
Updated by Shankar Narayanan 10 days ago
- Project changed from SP 11.3.2 to SP 11.3.2.2 Patches
- Issue Dependency set to Moved from SP11.3.2 to SP 11.3.2.2
- How do we missed in Testing ? deleted (
Impact of another change)
Updated by Manivannan Uppiliappan 6 days ago
- Tracker changed from Bug to Feature/Enhancement
- Status changed from Not Resolved to Suggestion
Actions