FSR- Higher ASIL Concepts fails by deleting and adding another function. (may need SME support)

Added by Vani Kunnatheri 3 months ago. Updated 6 days ago.

Status:
Suggestion
Priority:
Medium
Start date:
01/23/2025
Due date:
% Done:

0%

Estimated time:
Steps To Reproduce:

1.Locate 3 different safety goals
2.add same function across all
3.Delete the function from highest one
4.Add a new function
5.Observe

MODULES:
FST
Build Cycle:
Cycle 3
Customer:
Issue Dependency:
Moved from SP11.3.2 to SP 11.3.2.2
Dev Commitment to Resolve in::

Description

I used 3 different safety goals standard D, standard B and non standard C
Added the same function across all 3 safety goals

Then deleted the function from ASIL D safety goal, works as expected

Then added a new function for ASIL D, this time Higher asil concept fails