Bug #29452
closedGage rr Part wise Schedule: - "After performing the GRR study, the Gage Number cannot be opened in the Gage R&R Part-Wise screen. As a result, the user is unable to edit the Part Name or view details of other studies, such as Bias, Linearity, Type 1 data,
0%
1. Login EWQIMS as MSA Module admin/user
2. Create a Gage RR Part as variable Gages
3. Click on Gage RR and ---> Click Measurement System Definition----> Create Grp Name with Gage type/Gages
4. Click on Conduct Gage RR
5. Select the Type information and Select the created Group name ---->Select the Gage Number
6. Click On New Button
7. Click ON all Mandatory Fields -->Click On save Button---> Performed The Study with Pending close/Out [or] Completed Status.
2. Click on MSA-Setup Menu->Click on Gage RR Part wise menu
4. Click On created GageRR part
5.Try to Edit the Event Description /Classifications/Part name/Part characteristics
7.Observe the Behaviour
Description
Issue 1: - can't seen Study dates Frequency's Due dates
Suggestion: - Provide Facility to Open Gage Number Page wise schedule Screen
Files