Failure Analysis - Allocated the Risk in the 'IFM' and then deallocated it, but instead of deallocating the IFM-allocated Flowdown branches, the existing Failure Flowdown branch was deallocated.

Added by Gopinath Ramamoorthy 9 months ago. Updated 7 months ago.

Status:
Closed
Priority:
Medium
Assignee:
Start date:
09/25/2024
Due date:
% Done:

0%

Estimated time:
Steps To Reproduce:

1. Log in to the VDA.
2. Select the Failure Analysis.
3. Select the PI.
4. Add the Failure Flowdown.
5. Select the IFM and allocate the Risk for the same element for which flowdown is done.
6. Right-click and deallocate the added Risk.
7. Select the Failure Analysis.
8. Observe the result - The added Failure Flowdown is removed.

MODULES:
VDA
Build Cycle:
Cycle 1
Customer:
Issue Dependency:
Dev Commitment to Resolve in::

Description

Allocated the Risk in the 'IFM' and then deallocated it, but instead of deallocating the IFM-allocated Flowdown branches, the existing Failure Flowdown branch was deallocated.


Files

55.png (117 KB) 55.png Gopinath Ramamoorthy, 09/25/2024 01:33 PM
56.png (111 KB) 56.png Gopinath Ramamoorthy, 09/25/2024 01:33 PM
Actions #1

Updated by Gopinath Ramamoorthy 9 months ago

Actions #2

Updated by Reng Raj 8 months ago

  • Status changed from New to Open
  • Assignee changed from chitra Kalangiam to Manivannan Uppiliappan
Actions #3

Updated by Manivannan Uppiliappan 8 months ago

  • Assignee changed from Manivannan Uppiliappan to Manoj Kumar
Actions #4

Updated by Manoj Kumar 8 months ago

  • Status changed from Open to Fixed in Dev
Actions #5

Updated by Manoj Kumar 8 months ago

  • Status changed from Fixed in Dev to Resolved
Actions #6

Updated by Gopinath Ramamoorthy 7 months ago

  • Status changed from Resolved to Closed