Project

General

Profile

Actions

Bug #28865

closed

HARA - Exposure Value Update Fails to Recalculate ASIL When another Malfunction Branch Is Empty; Requires Manual Page Refresh

Added by Vani Kunnatheri 9 months ago. Updated 8 months ago.

Status:
Closed
Priority:
Medium
Start date:
08/08/2024
Due date:
% Done:

0%

Estimated time:
Steps To Reproduce:

1.Log into FST
2.Select HARA analysis page
3.Select the Focus Element
4.Add an operational situation , exposure, malfunction , failure mode, effect , severity , controllability and safety goal.
5.Add another malfunction branch and add malfunction and failure mode.
6.Update the exposure value and observe

MODULES:
FST
Build Cycle:
Cycle 1
Customer:
Issue Dependency:
Dev Commitment to Resolve in::

Description

Under one operational situation, if there are 2 malfunction branches and one of them is empty without an effect or details, updating the exposure value will not automatically recalculate the ASIL until the page is manually refreshed.


Files

Exposure update.png (57.7 KB) Exposure update.png Vani Kunnatheri, 08/08/2024 06:49 PM