Actions
Feature/Enhancement #28640
openDesign AIAG VDA: Deleting the Optimization from the VDA module and opening the DFMEA table, the optimization branch is not deleted, and the severity, occurrence, detection and AP values are not deleted.
Start date:
07/23/2024
Due date:
% Done:
0%
Estimated time:
Steps To Reproduce:
1.Login as AQuA Pro Module Administrator
2.Click on EWIQMS icon.
3.Select the EVAV NPD/APQP Platform
4.Select the Product.
5.Click on the AIAG-VDA Design Menu.
6.Expand Global PI and Select a Production Item.
7.Select Failure Analysis
8.Delete optimization
9.Open DFMEA table
10.Observet the Result (Optimization branch)
MODULES:
VDA
Build Cycle:
Cycle 2
Customer:
Issue Dependency:
Moved from SP11.3.2 to SP 11.3.2.2
Dev Commitment to Resolve in::
Description
Design AIAG VDA: When deleting the Optimization (Prevention and Detection) from the VDA module and opening the DFMEA table, the optimization branch is not deleted, and the severity, occurrence, detection and AP values are not deleted.
Files
Actions