Project

General

Profile

Actions

Bug #28592

closed

Safety Goal - Safe State and Safety Goal Separation Bug When Adding Fault-Tolerant Time Interval and Rationale in the safe state page - No alert in Safety goal page when adding safe state first then Safety goal.

Added by Vani Kunnatheri 11 months ago. Updated 11 months ago.

Status:
Closed
Priority:
Medium
Start date:
07/17/2024
Due date:
% Done:

0%

Estimated time:
Steps To Reproduce:

1.Loh into FST
2.Select safety goals page
3.Add a safe state first
4.MAp a safety goal then.
5.Go to safe state page.
6.Add fault tolerant time interval and rationale for the same safe state.
7.Go to safety goal and observe

MODULES:
FST
Build Cycle:
Cycle 1
Customer:
Issue Dependency:
Dev Commitment to Resolve in::

Description

Adding a safe state first, then a safety goal in the Safety Goal page, then opening the Safe State page and adding a fault-tolerant time interval and rationale against the same safe state causes the safe state and safety goal to be separated into two rows on the Safety Goal page.
Additionally, each time a safe state is created in this manner, it creates branches under the safety goal page.


Files

safety goal -1.png (50.1 KB) safety goal -1.png Vani Kunnatheri, 07/17/2024 08:31 PM
safe state 1.png (17.8 KB) safe state 1.png Vani Kunnatheri, 07/17/2024 08:31 PM
safety goal -2.png (47.5 KB) safety goal -2.png Vani Kunnatheri, 07/17/2024 08:31 PM
multibranches-safety goal.png (98.1 KB) multibranches-safety goal.png Vani Kunnatheri, 07/17/2024 08:31 PM
Actions