Bug #28224
closedTSR-After deallocating the older ASIL from the FSR, technical functions and requirements of an allocated element with the previous ASIL still appear for the changed ASIL allocation.
0%
1.Log into FST
2.Select FSR page from the Menu
3.Add a function and Requirement against a safety goal.
4.Allocate to one element an ASIL value .
5.Go to TSR page.
6.Add two functions and Requirements against the Element.
7.Go to FSR and Deallocate the ASIL
8.Please observe the TSR
9.Re allocate other ASIL value for the same element.
10.Go to TSR and observe.
Description
After deallocating the older ASIL from the FSR, technical functions and requirements of an allocated element with the previous ASIL still appear for the changed ASIL allocation.
Tried Deallocate, then assign a new one instead of directly changing the ASIL.
Allocated ASIL D for ECU in FSR
Added two functions and Requirements in TSR page
Deallocated ASIL D from FSR , and Functions and requirements along with ASIL removed from TSR.
Allocated a non standard B for ECU , the same functions and requirements existed for ASIL D showed up.
Files
Updated by Vani Kunnatheri 11 months ago
- Description updated (diff)
Updated by Manivannan Uppiliappan 11 months ago
- Assignee changed from Manivannan Uppiliappan to Manoj Kumar
Updated by Shankar Narayanan 10 months ago
- Project changed from SP 11.2.0.15 Patches to SP 11.2.0.16 Patches
Updated by Vani Kunnatheri 9 months ago
- Status changed from Resolved to Not Resolved
Technical function and Requirement still appear for changed ASIL Allocation after deallocating from FSR.
Updated by Manoj Kumar 9 months ago
- Status changed from Not Resolved to Fixed in Dev
Updated by Manoj Kumar 9 months ago
- Status changed from Fixed in Dev to Resolved