Project

General

Profile

Actions

Feature/Enhancement #26977

open

Edit Risk popup window AP value is not calculated in the flow-up failure severity value, which is calculated by default using only the Direct effect. (Refer Description) NEED MARK'S SUPPORT

Added by Kirubakaran chandran over 1 year ago. Updated 8 days ago.

Status:
Open
Priority:
Medium
Start date:
12/18/2023
Due date:
% Done:

0%

Estimated time:
Steps To Reproduce:

1. Login as Aqua pro module Administrator
2. Click on the product (Aqua Pro) menu
3. Click on Design VDA and select Failure Analysis
4. Expand the Tree
5. Assign Flow-up failure severity
6. Right-click on Risk (preventive/Detective)
7. Click on Edit
8. Edit Risk pop window will be open
9. Observe the result
10. Go to the DFMEA table (Select Higher context Element)
11. Observe the result

MODULES:
VDA
Build Cycle:
Cycle 0
Customer:
Issue Dependency:
Moved from SP11.3.2 to SP 11.3.2.2
Dev Commitment to Resolve in::

Description

The system displayed an AP value in the Design VDA Edit Risk popup window.
The displayed AP value is not calculated in the flow-up failure severity value, which is calculated by default using only the Direct effect.
EX. DFMEA table (Flow-up failure Severity-2, Occurrance-5, Detection-3) AP value = L
Edit Risk Popup window displayed AP value is H (System calculate Direct Effect Severity-10, Occurrance-5, Detection-3)

Refer TC: http://14.194.186.13:8080/testlink/linkto.php?tprojectPrefix=EwQIMS&item=testcase&id=EwQIMS-27496


Files

1. Edit Risk.png (177 KB) 1. Edit Risk.png Kirubakaran chandran, 12/17/2023 03:23 AM
2. DFMEA table.png (152 KB) 2. DFMEA table.png Kirubakaran chandran, 12/17/2023 03:23 AM
Actions

Also available in: Atom PDF