Bug #25774
closedDesign VDA Structure analysis Remove the BoM issue, and Expand the arrow issue (Refer description)
0%
1. Login as AQuA Pro Module Administrator
2. Click on the EWQIMS icon and select EVAV NPD/APQP Platform
3. Click on the Products(Aqua Pro) menu
4. Click on Design VDA and select Structure Analysis
5. Select Production Item
6. Click on "+" icon (To add multiple BoM)
7. Click on Remove icon "X" in any in-between Bom
8. Double Click on Arrow symbol and verify
Description
1. When I create multiple BoM (Example: 4 BoM created), then I want to remove the second BoM, I click the remove icon "X" and the system removes the BoM. (2,3,4)
Refer TC: http://saas.omnex.in:81/testlink/linkto.php?tprojectPrefix=EwQIMS&item=testcase&id=EwQIMS-22051
2. Created the same subsystems, I expand one system, then expand another, with the first system also displaying an expand arrow.
3. Double Click on the Arrow symbol system to collapse the BoM
Refer TC: http://saas.omnex.in:81/testlink/linkto.php?tprojectPrefix=EwQIMS&item=testcase&id=EwQIMS-22241
4. Structure Analysis: cloor legend pop window all column is editable
Files
Updated by Kirubakaran chandran almost 12 years ago
- File legend color pop window.png legend color pop window.png added
- Description updated (diff)
Updated by chitra Kalangiam almost 12 years ago
- Assignee changed from chitra Kalangiam to Manoj Kumar
Updated by Manoj Kumar almost 12 years ago
- Status changed from Open to Fixed in Dev
Updated by Manoj Kumar almost 12 years ago
- Status changed from Fixed in Dev to Fixed with Hotfix
Updated by Kirubakaran chandran over 11 years ago
- Status changed from Fixed with Hotfix to Resolved
Updated by Shankar Narayanan over 1 year ago
- Status changed from Resolved to Closed