LPA Schedule->Equipment Selection Window->Validation message is missing

Added by Raja S almost 8 years ago. Updated almost 8 years ago.

Status:
Closed
Priority:
Low
Assignee:
Start date:
06/22/2017
Due date:
% Done:

100%

Estimated time:
Steps To Reproduce:

1.Login as module admin
2.Expand administrator tab
3.Click on LPA Schedule link
4.Click on Equipment selection icon
5.Select the equipment which is not having checklist
6.Click on done button

MODULES:
AUDITPRO
Build Cycle:
Cycle 1
Customer:
Issue Dependency:
Dev Commitment to Resolve in::

Description

LPA Schedule->Equipment Selection Window->Need validation when clicks on Done button with equipment(s) which is not having checklist.


Files

A2.PNG (115 KB) A2.PNG Anonymous, 07/03/2017 12:21 PM
A1.PNG (107 KB) A1.PNG Anonymous, 07/03/2017 12:21 PM
A3.PNG (86.5 KB) A3.PNG Anonymous, 07/03/2017 12:21 PM
Actions #1

Updated by Anonymous almost 8 years ago

  • Status changed from New to Open
Actions #2

Updated by Raja S almost 8 years ago

  • Subject changed from LPA Schedule->Equipment Selection Window->Vaalidation message is missing to LPA Schedule->Equipment Selection Window->Validation message is missing
Actions #3

Updated by Bijoy P almost 8 years ago

  • Assignee changed from Bijoy P to Anonymous
Actions #4

Updated by Bijoy P almost 8 years ago

Please do not list equipment which is not assigned check list / check point in scheduling screen

Actions #5

Updated by Anonymous almost 8 years ago

  • Status changed from Open to In Progress
  • Assignee changed from Anonymous to Nikhil d
Actions #6

Updated by Nikhil d almost 8 years ago

  • Status changed from In Progress to Fixed in Dev
  • % Done changed from 0 to 100
Actions #7

Updated by Anonymous almost 8 years ago

  • Status changed from Fixed in Dev to Resolved

Updated by Anonymous almost 8 years ago

the equipment is not listing when there is not checklist is assigned to equipment