Project

General

Profile

Actions

Bug #15133

closed

Main2: D/PFMEA, Effects Column the Severity Value is not updating correctly

Added by Anonymous over 5 years ago. Updated over 5 years ago.

Status:
Closed
Priority:
High
Assignee:
-
Start date:
11/27/2019
Due date:
% Done:

0%

Estimated time:
Steps To Reproduce:

1.Login as AQuAPro Module User

2.Click on AQuAPro Tab -> Main2

3.Expand Global PI -> Select any of the PI

4.Click on Process/Design Documents -> Open any of the Documents (E.g.: PFMEA)

5.Double-Click on Empty Cell in the Effects Column -> Set the Severity Value for Multiple Effects

6.Press "Ctrl+Mouse Click" select the Multiple Effects which the Severity Value Set -> Click on OK Button

7.View the Effects and its Severity Values for the selected Effects

8.Observe the Result

MODULES:
AQUAPRO
Build Cycle:
Cycle 3
Customer:
Issue Dependency:
Dev Commitment to Resolve in::

Description

In D/PFMEA, When the User tries to add different Severity Values for Multiple Effects and selecting those Effects as Multiple and Clicking on OK Button and by viewing those items in the Effects Cell its updating wrongly

For Ex: If am Selecting 3 Effects and Setting 3 different Severity, "Effect1, Sev-7", "Effect2, Sev-9", "Effect3, Sev-6" and by clicking OK Button and viewing in the Cell it displays as "Effect1, Sev-7", "Effect2, Sev-7", "Effect3, Sev-7"


Files

Actions #1

Updated by User Admin over 5 years ago

  • Status changed from New to Open
Actions #2

Updated by Anonymous over 5 years ago

  • Status changed from Open to Resolved
Actions #3

Updated by Anonymous over 5 years ago

  • Status changed from Resolved to Closed
Actions #4

Updated by Anonymous over 5 years ago

Working as expected so closing this issue on 28.11.2019 in Cycle-4