Bug #15078
closedMain2: D/PFMEA, Cause Column, Multi-Select is not working throwing unwanted message (With Multi-Select)
0%
1.Login as AQuAPro Module User
2.Click on AQuAPro Tab -> Main2
3.Expand Global PI -> Select any of the PI
4.Click on Process/Design Documents -> Open any of the Documents (E.g.: PFMEA)
5.Double-Click on the New Cell in the Cause Column -> Select the listed Causes as Multiple by pressing Ctrl+Mouse Click
6.Click on OK Button
7.Observe the Result
Description
In the Cause Column, When the User tries to Select the Multiple Causes in the New Cell and clicking on OK Button its not updating the selected Causes and its throwing unwanted message as "Cannot insert duplicate key row in object 'dbo.AssocInstReuse' with unique index 'IX_AssocInstReuse2'. The duplicate key value is (22360, 29, 21360, <NULL>, 21363, 0).
The statement has been terminated."
Files
Updated by Anonymous over 5 years ago
- Status changed from Open to Resolved
For now, cannot make Cause as Multi select as need to discuss with Mark, so restricted to show multi dropdown for cause
Updated by Anonymous over 5 years ago
- Status changed from Resolved to Closed
Working as expected so closing this issue on 27.11.2019 in Cycle-3. As per the Dev Team comment QA is closing this issue as of now