Bug #11830

closed

VOC - Function and Requirement created in FSR document is displayed along with the Function and Requirement created in IFM in same VOC row.(Refer Description)

Added by Shankar Narayanan about 6 years ago. Updated almost 6 years ago.

Status:
Closed
Priority:
Medium
Start date:
04/03/2019
Due date:
% Done:

0%

Estimated time:
Steps To Reproduce:

1.Login as FST module administrator
2.Click on main and select any PI
3.Add a function and Requirement in VOC
4.Add a function and Requirement in IFM
5.Go to FSR and Add function and Requirement
6.Allocate ASIL for that Function and Requirement
7.Observe the VOC of selected Focus element

MODULES:
FST
Build Cycle:
Cycle 6
Customer:
Issue Dependency:
Dev Commitment to Resolve in::

Description

Function and Requirement created in FSR document is displayed along with the Function and Requirement created in IFM in same VOC row.

Expected result: IFM row should be displayed different and FSR row should display different.

Observation: Whenever and Wherever a Function is created in RFD, VDA and FST (ie; Block diagram, IFM, FSR and TSR) without opening VOC, all the created functions are displayed in the same row.

But if a function is created after opening VOC and then the newly added Function is displayed in Different row.


Files

2019-04-03 VOC.png (76.4 KB) 2019-04-03 VOC.png Shankar Narayanan, 04/03/2019 05:27 PM
Actions #1

Updated by User Admin about 6 years ago

  • Status changed from New to Open
Actions #2

Updated by Shankar Narayanan about 6 years ago

  • Subject changed from VOC - Function and Requirement created in FSR document is displayed along with the Function and Requirement created in IFM in same VOC row. to VOC - Function and Requirement created in FSR document is displayed along with the Function and Requirement created in IFM in same VOC row.(Refer Description)
  • Description updated (diff)
Actions #3

Updated by Anonymous about 6 years ago

  • Assignee changed from Anonymous to Anonymous
Actions #4

Updated by Anonymous about 6 years ago

  • Assignee changed from Anonymous to Shankar Narayanan

WAD

Actions #5

Updated by User Admin about 6 years ago

Need to verify the SRS, But even though in SRS this is needs to be addressed, This not seems to be a WAD.

as this is working  as expected  when we visited the  VOC once ,  and Go back again  and creating a function/Requirement in FSR
Actions #6

Updated by Anonymous almost 6 years ago

  • Status changed from Open to Resolved
Actions #7

Updated by User Admin almost 6 years ago

  • Status changed from Resolved to Closed

As per the Current Desing technical safety items is only separate Group. Next release all these group dependency will remove.