Actions
Bug #10590
closedIE and Chrome Main 2: Double Click on potential Effect of failure,dialog box will display then click on any other column or header or PI the dialog box still be displaying
Start date:
01/10/2019
Due date:
% Done:
0%
Estimated time:
Steps To Reproduce:
1.open process FMEA
2.Double Click on Potential Effects of Failure
3.Verify the Dialog box
4.Without clicking ok or cancel button
5.Click on any other Column or header
6.Check for Dialog box is still Remaining
7.Observe the Result
MODULES:
AQUAPRO
Build Cycle:
Cycle 4
Customer:
Micron phase 4
Issue Dependency:
Dev Commitment to Resolve in::
Description
When Double click on Potential Effect of failure and click on process Effects a dialog box will display on the screen then click on any other column or header or PI the dialog box will still be Display on the screen.please verify the attachment
Files
Updated by Iyappan hariharan over 6 years ago
- Status changed from Open to In Progress
Updated by Iyappan hariharan over 6 years ago
- Status changed from In Progress to Resolved
Fixed and patches applied on Micron Dev
Updated by Anonymous over 6 years ago
- File Dialog box is displaying and click on any other cloumn is get disappear issue is fixed.mp4 Dialog box is displaying and click on any other cloumn is get disappear issue is fixed.mp4 added
- Status changed from Resolved to Closed
It is working properly on 16/01/2019.Please verify the attachment.
Actions