Apply Clear
I check PCM2 and PCM5 and leave PCM3 checked:
And press OK.
ALL 6 PCM-SMs get included in the DFMEA and therefore appear in the Add Probability dialog (see below). The current SMs section has been photoshopped to show all 7 PCM-SMs.
Display Add Probability dialog for a DFailU/DFail.When two or more safety mechanisms are displayed in the listbox at the bottom, the OK and Cancel buttons are shifted down and no longer available:
You can see the OK and Cancel buttons getting shifted down, which should not happen:
And press the delete key to erase the value and then tab off the field, the Total Distribution is not recalculated. Even though the dialog recalculates when all fields contain a numeric value and a user tabs to another field, as soon as a blank is entered, recalculation does not occur.
Note that values are saved in the DB, so if I re-edit the FM Dist values, what I entered are still there.
In the SRS, the sample Edit FM Dist dialog shows <Comp Name> which is a way to indicate that it should be replaced with the Comp Name’s Name:So, the Edit FM Dist dialog at the top of this section should have a title of Edit FM Distribution Values for FF Carb Failures. Do not use () to enclose the component name and also leave a space after the word for.
Also available in: Atom CSV PDF
Selected Columns All Columns
Encoding ISO-8859-1 UTF-8