Functional Analysis - After adding the requirement flow down, instead of displaying one function flowdown, two function flowdowns were displayed. (Refer Description)

Added by Gopinath Ramamoorthy 14 days ago. Updated 10 days ago.

Status:
Closed
Priority:
Medium
Start date:
05/23/2025
Due date:
% Done:

0%

Estimated time:
Steps To Reproduce:

1. Log in to the VDA.
2. Select the Functional Analysis.
3. Select the Production Item.
4. Add one Function and two Requirements for the focus branch.
5. Add a Requirement flow down.
6. Add multiple requirements under the same function as a flow down.
7. Observe the result.

MODULES:
VDA
Build Cycle:
Cycle 1
Customer:
Issue Dependency:
Dev Commitment to Resolve in::
ISSUE TYPE:
NEW Due to Impact

Description

  1. After adding the requirement flow down, instead of displaying one function flowdown, two function flowdowns were displayed.
  2. When multiple requirements are allocated for a single Function flow down, only the last updated Requirement is displayed in the Tree Diagram.
  3. After collapsing and expanding, the flowdown branches are not displayed.

Files

118.png (40.7 KB) 118.png Gopinath Ramamoorthy, 05/23/2025 04:42 PM
119.png (83.5 KB) 119.png Gopinath Ramamoorthy, 05/23/2025 04:42 PM
clipboard-202505271314-aalvu.png (83.8 KB) clipboard-202505271314-aalvu.png Gopinath Ramamoorthy, 05/27/2025 01:14 PM
Actions #1

Updated by Gopinath Ramamoorthy 14 days ago

  • Description updated (diff)
Actions #2

Updated by Manivannan Uppiliappan 14 days ago

  • Status changed from New to Open
  • Assignee changed from chitra Kalangiam to Manivannan Uppiliappan
Actions #3

Updated by Manivannan Uppiliappan 11 days ago

  • Status changed from Open to Fixed in Dev
Actions #4

Updated by Manivannan Uppiliappan 11 days ago

  • Status changed from Fixed in Dev to Resolved
Actions #5

Updated by Gopinath Ramamoorthy 10 days ago

Actions