Bug #25420
closedDesign VDA - Structure Analysis - Need some changes in new UI for Structure Analysis.(Refer Description)
0%
1. Log in to the VDA module
2. Select Design VDA and open Structure Analysis menu
3.Follow description
Description
1.System should not allow to add next level element without populating the previous level branch.(Should popup an alert message)
2.When opening multiple new branches, on closing one branch it is closing all the branches.
3.While adding the new PI name, it is adding very slowly.
4.When right clicking on any of the lower level BOM elements and adding the new BOM element, it is showing the Top level parent element instead of the selected element in the popup.
5.Selecting an existing element from the popup, is saving the same PI directly under global even if we select some other element in the Part family column.
6.System is not showing the PI which is created under any other PI in Part family in the search box.
7.Text wrap is not done properly.
Files
Updated by Shankar Narayanan almost 12 years ago
- Project changed from SP 11.2.0.1 to SP 11.2.0.2 HF
Moved from Sp11.2.0.1
Updated by User Admin over 2 years ago
- Project changed from SP 11.2.0 to SP 11.2.0.1
- Build Cycle changed from Cycle 7 to Cycle 0
Updated by Reng Raj over 2 years ago
- Status changed from Open to Fixed in Dev
- Assignee changed from chitra Kalangiam to Manivannan Uppiliappan
Updated by Reng Raj over 2 years ago
- Status changed from Fixed in Dev to Fixed with Hotfix
Updated by Shankar Narayanan over 2 years ago
- Status changed from Fixed with Hotfix to Not Fixed with Hotfix
1.System should not allow to add next level element without populating the previous level branch.(Should popup an alert message) - Not fixed
2.When opening multiple new branches, on closing one branch it is closing all the branches. - Not Fixed
3.While adding the new PI name, it is adding very slowly. - Fixed
4.When right clicking on any of the lower level BOM elements and adding the new BOM element, it is showing the Top level parent element instead of the selected element in the popup. - Not Fixed
5.Selecting an existing element from the popup, is saving the same PI directly under global even if we select some other element in the Part family column. - Not Fixed
6.System is not showing the PI which is created under any other PI in Part family in the search box. - Not Fixed
7.Text wrap is not done properly. - Fixed
Updated by chitra Kalangiam over 2 years ago
- Status changed from Not Fixed with Hotfix to Fixed in Dev
Updated by chitra Kalangiam over 2 years ago
- Status changed from Fixed in Dev to Fixed with Hotfix
Updated by Shankar Narayanan over 2 years ago
System is not showing the PI which is created under any other PI in Part family in the search box. - Not Fixed
Updated by Shankar Narayanan over 2 years ago
- Status changed from Fixed with Hotfix to Not Fixed with Hotfix
Updated by Manivannan Uppiliappan over 2 years ago
- Status changed from Not Fixed with Hotfix to Fixed in Dev
Updated by Manivannan Uppiliappan over 2 years ago
- Status changed from Fixed in Dev to Fixed with Hotfix
Updated by Shankar Narayanan over 2 years ago
- Status changed from Fixed with Hotfix to Resolved
Updated by Shankar Narayanan over 1 year ago
- Status changed from Resolved to Closed