Actions
Bug #15353
closedD/PFMEA: In Potential Causes of Failure Column, By Clicking on Show Overrides/Change Levels its displaying Alert Message (Before SP920 it worked fine)
Start date:
01/03/2020
Due date:
% Done:
0%
Estimated time:
Steps To Reproduce:
1.Login as AQuAPro Module User
2.Click on AQuAPro Tab -> Main/Main2
3.Expand Global PI -> Select any of the PI
4.Click on Process Documents -> Open PFMEA Document
5.Right-Click on the Potential Causes of Failure Column Cell -> Click on the Show Overrides/Change Levels option
6.Observe the Result
MODULES:
AQUAPRO
Build Cycle:
Cycle 3
Customer:
Issue Dependency:
Dev Commitment to Resolve in::
Description
In Potential Causes of Failure Column, By Clicking on Show Overrides/Change Levels its displaying Alert Message as "You must select a single item within the cell" (Before SP920 it worked fine that also attached)
Files
Updated by Iyappan hariharan over 5 years ago
Fixed and patches shared for testing
Updated by Iyappan hariharan over 5 years ago
- Status changed from Open to Resolved
Fixed and patches shared for testing
Updated by Anonymous over 5 years ago
- Status changed from Resolved to Not Fixed with Hotfix
Updated by Iyappan hariharan over 5 years ago
- Status changed from Not Fixed with Hotfix to Resolved
Patch has applied now
Updated by Anonymous over 5 years ago
- Status changed from Resolved to Fixed with Hotfix
Updated by Anonymous over 5 years ago
- Status changed from Fixed with Hotfix to Closed
This issue is fixed so closing this issue in Cy-5 on 24.01.2020
Updated by Anonymous about 5 years ago
- File SP925 Closed Issue Reopened in SP1000.jpg SP925 Closed Issue Reopened in SP1000.jpg added
- Project changed from SP925 to SP 10.0.0
- Status changed from Closed to Reopen
Updated by Anonymous about 5 years ago
- Build Cycle changed from Cycle 2 to Cycle 3
Actions