Actions
Bug #12816
closedDesign VDA - Function/Failure Analysis - While performing Skip level Flowdown, system displays the function for the placeholder along with the target element in Diagrammatic view.
Start date:
06/26/2019
Due date:
% Done:
100%
Estimated time:
Steps To Reproduce:
1.Login as AQuA Pro Module Administrator
2.Click on AQuA Pro Tab and click on Main Menu
3.Expand the Global PI and select the PI
4.Click on Design Documents Menu and click on AIAG VDA DFMEA, new tab will open
5.Click on AIAG VDA Design tab and click on Functional/Failure Analysis
6.Perform skip level flowdown
7.In Diagrammatic view, Placeholder is displayed along with the flowdown element
MODULES:
VDA
Build Cycle:
Cycle 1
Customer:
Issue Dependency:
Dev Commitment to Resolve in::
Description
Place holder is displayed with the same function of the child function
Files
Updated by Shankar Narayanan almost 6 years ago
- File 2019-07-03 sKIP 2.png 2019-07-03 sKIP 2.png added
All the contents are duplicated
Updated by Reng Raj almost 6 years ago
- Status changed from In Progress to Resolved
Updated by Shankar Narayanan almost 6 years ago
- File 2019-07-12 sKIP.png 2019-07-12 sKIP.png added
- Status changed from Resolved to Not Fixed with Hotfix
Updated by Reng Raj almost 6 years ago
- Status changed from Not Fixed with Hotfix to In Progress
Updated by Reng Raj almost 6 years ago
- Status changed from In Progress to Resolved
Updated by Shankar Narayanan almost 6 years ago
- Status changed from Resolved to Not Resolved
If as kip level flowdown is done in Failure Analysis, then the Placeholder allocation is displayed in Functional Analysis.
Updated by Reng Raj almost 6 years ago
- Status changed from Not Resolved to Resolved
Updated by Shankar Narayanan almost 6 years ago
- Status changed from Resolved to Fixed with Hotfix
Updated by Shankar Narayanan almost 6 years ago
- Status changed from Fixed with Hotfix to Closed