Bug #11641

closed

AIAG VDA Process - Failure Analysis - While selecting operations/Segments/Production Item randomly, system displays random data in the Tree/Table view and Diagrammatic view.(Refer attachment)

Added by Shankar Narayanan about 6 years ago. Updated over 1 year ago.

Status:
Closed
Priority:
High
Assignee:
-
Start date:
03/25/2019
Due date:
% Done:

0%

Estimated time:
Steps To Reproduce:

1.Login as AQuA Pro Module Administrator
2.Click on AQuA Pro Tab and click on Main Menu
3.Expand the Global PI and select the PI
4.Click on Process Documents Menu and click on Structure Analysis
5.In Failure Analysis Add Segment and Operations and 4M
6.Create and Add Characteristics and Failure for Operation
7.Click on any Segment and Observe the result in Diagrammatic view
8.Click on some other operation or segments and Observe the result in Diagrammatic view

MODULES:
VDA
Build Cycle:
Cycle 5
Customer:
Issue Dependency:

Description

While selecting any segment, only limited operations and Categories are displayed in the List both in Tree and Table view


Files

Actions #1

Updated by Smitha V about 6 years ago

  • Status changed from New to Open
Actions #2

Updated by Shankar Narayanan about 6 years ago

  • Subject changed from AIAG VDA Process - Function/Failure Analysis - While selecting operations/Segments/Production Item randomly, system displays random data in the Tree/Table view and Diagrammatic view.(Refer attachment) to AIAG VDA Process - Failure Analysis - While selecting operations/Segments/Production Item randomly, system displays random data in the Tree/Table view and Diagrammatic view.(Refer attachment)
  • Steps To Reproduce updated (diff)
Actions #3

Updated by Reng Raj about 6 years ago

  • Status changed from Open to Resolved
Actions #4

Updated by Shankar Narayanan about 6 years ago

  • Status changed from Resolved to Not Fixed with Hotfix

After selecting any one existing operation and switching to Table view, only that operation is displayed even after clicking on the segment.

Actions #5

Updated by Reng Raj about 6 years ago

  • Status changed from Not Fixed with Hotfix to Resolved
Actions #6

Updated by Anonymous about 6 years ago

This issue is fixed in diagrammatic view but not fixed in table view.so this issue is not fixed.please verify the attachment.

Actions #7

Updated by Reng Raj about 6 years ago

  • Status changed from Not Resolved to In Progress
Actions #8

Updated by Anonymous about 6 years ago

  • Assignee changed from Reng Raj to Shankar Narayanan

This need time, because when we fixing neither scenario gets opened. So Kindly move this to next release.

Actions #9

Updated by User Admin about 6 years ago

  • Status changed from In Progress to TBD

This needs to be fixed as earliest this is a high priority issue in the User Flow. Expecting the fix in the Next Sprint Itself.

Actions #10

Updated by User Admin about 6 years ago

  • Status changed from TBD to Future Release

This needs to be fixed as earliest this is a high priority issue in the User Flow. Expecting the fix in the Next Sprint Itself. This issue and 11777 issues are so Critical and needs to be get addressed.

But This two issues are needs to be addressed in the next build or expecting a Hotfix as earliest without his we cant sign off SP900.

Actions #11

Updated by Shankar Narayanan about 6 years ago

  • Assignee changed from Shankar Narayanan to Anonymous
Actions #12

Updated by Shankar Narayanan over 5 years ago

  • Project changed from SP900 EwIMS to Known Issue
Actions #13

Updated by User Admin over 1 year ago

  • Status changed from Future Release to Open
Actions #14

Updated by User Admin over 1 year ago

  • Status changed from Open to Closed

changed status as per shankar